help button home button JAMIA Bigger figures
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kahn, M. G.
Right arrow Articles by Fraser, V. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kahn, M. G.
Right arrow Articles by Fraser, V. J.

Journal of the American Medical Informatics Association, Vol 3, 216-223, Copyright © 1996 by American Medical Informatics Association


ARTICLES

Monitoring expert system performance using continuous user feedback

MG Kahn, SA Steib, WC Dunagan and VJ Fraser
Section of Medical Informatics, Division of General Medical Sciences, Washington University School of Medicine, St. Louis, MO, USA. kahn@informatics.wustl.edu

OBJECTIVE: To evaluate the applicability of metrics collected during routine use to monitor the performance of a deployed expert system. METHODS: Two extensive formal evaluations of the GermWatcher (Washington University School of Medicine) expert system were performed approximately six months apart. Deficiencies noted during the first evaluation were corrected via a series of interim changes to the expert system rules, even though the expert system was in routine use. As part of their daily work routine, infection control nurses reviewed expert system output and changed the output results with which they disagreed. The rate of nurse disagreement with expert system output was used as an indirect or surrogate metric of expert system performance between formal evaluations. The results of the second evaluation were used to validate the disagreement rate as an indirect performance measure. Based on continued monitoring of user feedback, expert system changes incorporated after the second formal evaluation have resulted in additional improvements in performance. RESULTS: The rate of nurse disagreement with GermWatcher output decreased consistently after each change to the program. The second formal evaluation confirmed a marked improvement in the program's performance, justifying the use of the nurses' disagreement rate as an indirect performance metric. CONCLUSIONS: Metrics collected during the routine use of the GermWatcher expert system can be used to monitor the performance of the expert system. The impact of improvements to the program can be followed using continuous user feedback without requiring extensive formal evaluations after each modification. When possible, the design of an expert system should incorporate measures of system performance that can be collected and monitored during the routine use of the system.


This article has been cited by other articles:


Home page
ANN INTERN MEDHome page
D. M. Bravata, K. M. McDonald, W. M. Smith, C. Rydzak, H. Szeto, D. L. Buckeridge, C. Haberland, and D. K. Owens
Systematic Review: Surveillance Systems for Early Detection of Bioterrorism-Related Diseases
Ann Intern Med, June 1, 2004; 140(11): 910 - 922.